• Test Item

    Test Method

    Measurement Value

    Remark

    (280-380nm)

    UV Cut-Off

    GB/T 2410-2008

    ≥95%

    Test with UV Spectrophotometer

    (400-1100nm)Transmittance

    ≥90%

    Tensile Strength

    GB/T1040.3-2006

    MD≥30MPa

    TD≥20MPa

    100mm/min

    Dumbbell shaped sample,

    100 mm/min rate of

    extension

    Elongation

    at Break

    GB/T1040.3-2006

    MD≥150%

    TD≥300%

    Surface Tension

    Corona Surface

    GB/T14216

    ≥48dyn/cm

    Dyne pen test

    Heat Shrinkage

    Rate

    GB/T12027

    MD≤4.0%

    TD≤1.5%

    150℃&30min

    PCT 96h

    Tensile Strength

    GB/T1040.3-2006

    MD≥30MPa

    TD≥20MPa

    100mm/min

    Dumbbell shaped sample,

    100 mm/min rate of

    extension

    PCT 96h

    Elongation at

    Break

    MD≥100%

    TD≥100%

    -40℃

    Tensile Strength

    MD≥30MPa

    TD≥20MPa

    -40℃

    Elongation

    at Break

    TD≥20%

    PCT 96h

    /


    Yellowing index

    △b≤3.0


    T:121℃, RH:100%, P:2atm,

    Time: 96h.

    UV300 kWh/㎡

    IEC61215


    The sample temperature is

    65±5℃, and total radiation

    dose is 300KWh•m2, UVB

    accounts for 3%-10%.


    DH2000h

    IEC61215


    Yellowing index

    △b≤3.0


    T: 85℃, RH: 85%, Time:

    2000h.


    TC400

    IEC61215


    T: -40℃~85℃, 6h/

    period, 400 period.